ISO13485:2016
ISO 13485:2016 is a standard that outlines the requirements for a quality management system (QMS) specific to the medical device industry. It provides a framework to ensure that medical devices consistently meet customer and regulatory requirements. Although it is based on ISO 9001, ISO 13485:2016 includes additional requirements and is more focused on regulatory compliance, risk management, and maintaining the effectiveness of the processes related to the lifecycle of medical devices.
Here’s a detailed overview of the clauses in ISO 13485:2016:
Clause 1: Scope
This clause specifies that the QMS is applicable to organizations involved in the life cycle of medical devices, including design, development, production, storage, distribution, installation, servicing, and final decommissioning or disposal of devices. It also applies to organizations providing related services (e.g., sterilization or calibration). The scope emphasizes meeting both customer requirements and regulatory requirements applicable to medical devices.
Key points:
- The standard can be applied by organizations involved in one or more stages of the medical device lifecycle.
- Organizations can also include QMS requirements for suppliers or external parties.
Clause 2: Normative References
There are no normative references in ISO 13485:2016, meaning that there are no other external documents that are considered indispensable for its application.
Clause 3: Terms and Definitions
ISO 13485:2016 makes use of the terms defined in ISO 9000:2015 (Quality management systems – Fundamentals and vocabulary), with additional medical device-related definitions. Key terms like “medical device,” “risk,” “sterilization,” and “regulatory requirements” are specifically defined to ensure clarity in the medical device context.
Clause 4: Quality Management System
This clause outlines the general requirements for establishing, documenting, implementing, and maintaining a QMS, with a focus on medical devices.
Key sub-clauses:
- 4.1 General Requirements: Organizations must develop a documented QMS that includes processes for risk management, compliance with regulatory requirements, and product realization.
- 4.2 Documentation Requirements: This includes requirements for maintaining controlled documents, procedures, and records. Organizations must have a documented quality manual and control procedures for managing changes and documentation.
Additional requirements for medical devices:
- Regulatory compliance must be a key component in the QMS.
- The organization must establish procedures for risk management throughout the product lifecycle.
Clause 5: Management Responsibility
Management plays a crucial role in the successful implementation and maintenance of the QMS. This clause focuses on the responsibilities of top management in ensuring the QMS meets the requirements of ISO 13485.
Key sub-clauses:
- 5.1 Management Commitment: Top management must demonstrate commitment to the QMS, customer focus, regulatory compliance, and product safety.
- 5.2 Customer Focus: Organizations must ensure that customer requirements and regulatory requirements are consistently met.
- 5.3 Quality Policy: Establish a quality policy that aligns with the organization’s strategy and objectives, with a focus on compliance and quality.
- 5.4 Planning: Management is responsible for setting measurable quality objectives and planning for the QMS.
- 5.5 Responsibility, Authority, and Communication: Roles, responsibilities, and authorities within the organization must be clearly defined and communicated.
- 5.6 Management Review: Regular management reviews are required to ensure the ongoing suitability, adequacy, and effectiveness of the QMS.
Medical device-specific requirements:
- Management reviews must include input on regulatory changes, product performance, and feedback from customers and regulatory authorities.
Clause 6: Resource Management
This clause covers the resources required to implement, maintain, and improve the QMS and ensure the conformity of medical devices.
Key sub-clauses:
- 6.1 Provision of Resources: The organization must provide the necessary resources to implement and maintain the QMS.
- 6.2 Human Resources: Personnel must be competent based on education, training, skills, and experience, and records of competencies must be maintained.
- 6.3 Infrastructure: Organizations must provide the infrastructure necessary for achieving conformity, including facilities, equipment, and supporting services.
- 6.4 Work Environment and Contamination Control: This includes ensuring a controlled work environment (e.g., cleanliness, contamination prevention), especially in areas where contamination could affect product safety or performance.
Medical device-specific requirements:
- Special attention is given to cleanliness and contamination control, particularly for sterile medical devices or devices intended for clean environments.
Clause 7: Product Realization
This clause focuses on the processes required to bring a medical device from conception to delivery. It is the most detailed section and includes provisions for planning, design, development, production, and post-production activities.
Key sub-clauses:
- 7.1 Planning of Product Realization: Organizations must plan product realization activities in line with the requirements for medical devices, taking into account risk management, product verification, and validation.
- 7.2 Customer-Related Processes: This includes determining customer requirements, reviewing customer contracts, and ensuring customer communication (e.g., complaints handling).
- 7.3 Design and Development: The design and development process must be planned and controlled, with risk management and validation of design outputs included.
- 7.4 Purchasing: Organizations must control the purchasing process to ensure that purchased products conform to specified requirements, including supplier evaluation and monitoring.
- 7.5 Production and Service Provision: This includes production control, validation of special processes (e.g., sterilization), and identification and traceability of products.
- 7.6 Control of Monitoring and Measuring Equipment: Organizations must ensure that equipment used for monitoring and measuring is properly calibrated and maintained.
Medical device-specific requirements:
- Risk management must be integrated into every stage of product realization, from design to production.
- Special processes such as sterilization and packaging must be validated.
- Traceability is crucial, especially for implantable devices, and must be maintained from raw material to finished product.
Clause 8: Measurement, Analysis, and Improvement
This clause addresses how organizations should monitor and measure the performance of the QMS, including how to address nonconformities and improve processes.
Key sub-clauses:
- 8.1 General: Organizations must monitor and measure QMS processes to ensure they meet the requirements for medical devices.
- 8.2 Monitoring and Measurement: This includes internal audits, monitoring customer satisfaction, and assessing the performance of products and processes.
- 8.3 Control of Nonconforming Product: Procedures must be in place to identify and control nonconforming products, including taking corrective action and, if necessary, recalling products.
- 8.4 Analysis of Data: Organizations must collect and analyze data on product performance, customer satisfaction, and process effectiveness.
- 8.5 Improvement: Organizations must take actions to improve the QMS through corrective and preventive actions, continual improvement, and addressing the root causes of nonconformities.
Medical device-specific requirements:
- Regulatory requirements for post-market surveillance, reporting, and vigilance must be integrated into the QMS.
- Nonconforming products, especially those that pose a risk to patient safety, must be managed with immediate corrective actions, including product recall if necessary.